From microsurgery to nanosurgery: how viral vectors may help repair the peripheral nerve.

Prog Brain Res. 2009; 175: 173-86Tannemaat MR, Boer GJ, Eggers R, Malessy MJ, Verhaagen JReconstructive surgery of the peripheral nerve has undergone major technical improvements over the last decades, leading to a significant improvement in the clinical outcome of surgery. Nonetheless, functional recovery remains suboptimal in the majority of patients after nerve repair surgery. In this review, we first discuss the molecular mechanisms involved in peripheral nerve injury and regeneration, with a special emphasis on the role of neurotrophic factors. We then identify five major challenges that currently exist in the clinical practice of nerve repair and their molecular basis. The first challenge is the slow rate of axonal outgrowth after peripheral nerve repair. The second problem is that of scar formation at the site of nerve injury, which is detrimental to functional recovery. As a third issue, we discuss the difficulty in assessing the degree of injury in closed traction lesions without total loss of continuity of the involved nerve elements. The fourth challenge is the problem of misrouting of regenerating axons. As a fifth and final issue we discuss the potential drawbacks of using sensory nerve grafts to support the regeneration of motoneurons. For all these challenges, solutions are likely to emerge from (a) a better understanding of their molecular basis and (b) the ability to influence these processes at a molecular level, possibly with the aid of viral vectors. We discuss how lentiviral vectors have been applied in the peripheral nerve to express neurotrophic factors and summarize both the advantages and drawbacks of this approach. Finally, we discuss how lentiviral vectors can be used to provide new, molecular neurobiology-based, approaches to address the clinical challenges described above.

Comparison of the effects of short- and long-pulse durations when using a 585-nm pulsed dye laser in the treatment of new surgical scars.

Lasers Med Sci. 2009 Aug 7; Nouri K, Elsaie ML, Vejjabhinanta V, Stevens M, Patel SS, Caperton C, Elgart GMore than 70 million surgical procedures are performed annually in the USA with the majority involving a skin lesion and almost all individuals in their lifetime will have one or more surgical procedures resulting in scars. Patients and physicians alike are thereby motivated to improve the cosmetic outcome of scars. Prior studies have shown that the pulsed dye laser (PDL) is effective in improving the quality and appearance of the scar when using the 585-nm PDL immediately after the removal of sutures. Most published studies used a pulse duration of 450 micros, which along with the other study parameters, has led to an overall improvement of the scars. However, a pulse duration of 1.5 ms is also available when using the pulsed dye laser and it should theoretically cause fewer side-effects. To our knowledge, there are no other studies comparing the effectiveness of different pulse durations in the treatment of surgical scars starting on the day of suture removal. The purpose of this study is to compare the effect of different pulse durations (450 micros vs. 1.5 ms) in the treatments of postsurgical linear scars immediately after suture removal when using the 585-nm pulsed dye laser (PDL). Twenty non-hospitalized male and female patients (older than 18 years of age) with skin types I-IV and with postoperative linear scars measuring at least 2.1 cm were enrolled in this prospective study. Scars were randomly divided into three equal sections. The different fields were randomly chosen to receive treatment (two out of three fields) or remain as control (one field). The two fields chosen to be treated received treatment with the 585-nm PDL using a 7-mm spot size at 4.0 J. One of the treated sections was randomly selected to receive a pulse duration of 450 micros, and the other section to receive a 1.5-ms pulse. The remaining scar section was designated as control (no treatment). The three sections were mapped and recorded. The patient received treatment immediately after the sutures were removed from the wound and then monthly for 3 months. Evaluations were performed before each treatment and 1 month after the last treatment. The short-pulse and long-pulse 585-nm PDL-treated sections demonstrated a statistically significant overall average improvement of the VSS of 92 and 89%, respectively, compared to 67% for the control site (Fig. 1). Further, for individual parameters of the Vancouver scar scale (VSS), there were significant (p < 0.05) differences between control and treatment groups for all parameters, but there were no differences between the short- and long-pulse treatment groups for any parameter. Both short-pulse and long-pulse PDL are safe and effective in improving the quality and cosmetic appearance of surgical scars in skin type's I-IV starting on the day of suture removal with no significant difference between the two pulse durations.

Catheter Ablation of Recurrent Scar-Related Ventricular Tachycardia Using Electroanatomical Mapping and Irrigated Ablation Technology: Results of the Prospective Multicenter Euro-VT-Study.

J Cardiovasc Electrophysiol. 2009 Jul 28; Tanner H, Hindricks G, Volkmer M, Furniss S, Kühlkamp V, Lacroix D, DE Chillou C, Almendral J, Caponi D, Kuck KH, Kottkamp HCatheter Ablation of Ventricular Tachycardia. Introduction: Ventricular tachycardia (VT) late after myocardial infarction is an important contributor to morbidity and mortality. This prospective multicenter study assessed the efficacy and safety of electroanatomical mapping in combination with open-saline irrigated ablation technology for ablation of chronic recurrent mappable and unmappable VT in remote myocardial infarction. Methods and Results: In 8 European institutions, 63 patients (89% males) were enrolled in the study. All patients had remote myocardial infarction and presented with a median number of 17 (range 1-380) VTs in the preceding 6 months. Incessant VT was present in 14 patients (22%). Left ventricular ejection fraction measured 30 +/- 13%. A mean of 3 VTs were targeted per patient and 22% of all patients had only unmappable VT. The mean follow-up period was 12 +/- 3 months. A total of 164 VTs were targeted during catheter ablation. Ablation was acutely successful in 51 patients (81%). One patient (1.5%) experienced a major complication with degeneration of VT into ventricular fibrillation necessitating cardiopulmonary resuscitation maneuvers. However, no death occurred acutely or within the first 30 days after catheter ablation. During the follow-up, 19 of the initially successful ablated patients (37%) and 31 of all ablated patients (49%) developed some type of VT recurrence. Conclusions: The results of this multicenter study demonstrate the high acute success rate and a low complication rate of irrigated tip catheter ablation of all clinical relevant VTs in remote myocardial infarction. However, during the follow-up a relevant number of recurrences occurred.

Kinematic evaluation of cruciate-retaining total knee replacement patients during level walking: A comparison with the displacement-controlled ISO standard.

J Biomech. 2009 Aug 1; Ngai V, Wimmer MADifferences between wear-scar features of simulator-tested and retrieved tibial total knee replacement (TKR) liners have been reported. This disagreement may result from differences between in vivo kinematic profiles and those defined by the International Organization for Standardization (ISO). The purpose of this study was to determine the knee kinematics of a TKR subject group during level walking and compare them with the motion profiles defined by the ISO standard for a displacement-controlled knee wear testing simulator. Twenty-nine patients with a posterior cruciate ligament-retaining TKR design were gait tested using the point cluster technique to obtain flexion-extension (FE) rotation, anterior-posterior (AP) translation and internal-external (IE) rotation knee motions during a complete cycle of level walking. Relative ranges of motion and timing of key points within the in vivo motion data were compared against the same ranges and same key points from the input profiles of the displacement-controlled wear testing standard ISO14243-3. The subjects exhibited a FE pattern similar to ISO, with an insignificant difference in range of FE rotation from midstance to terminal stance. However, the subjects had a significantly higher range of knee flexion from terminal stance into swing. The subjects also exhibited a phase delay for the entire gait cycle. For AP translation, the standard profile had statistically significant lower magnitudes than seen in vivo. Opposite pattern of AP motion was also apparent from midstance and swing. Similarly, ISO specified a smaller IE total range of rotation with a motion pattern in complete opposition to that seen in vivo. In conclusion, significant differences were found in both the magnitudes and pattern of in vivo motion compared with ISO.